ModMetric Controller C841X

The ModMetric Controller is designed for refrigeration equipment control. Built of Howe’s new flexible architecture, it can be programmed with a wide variety of auxiliary functions. With the ability to spec up to 4 10A relays, the 841X is the most capable and flexible small-formfactor controller on the market. The sleek capacitive touch face brings the look of modernity, designating the ModMetric as what a modern Controller should be.

  • Power Supply
    • 12VAC
    • 12DC
    • 110/120V
    • AC 60Hz
  • Outputs
    • Compressor Relay, 10A, SPST
    • Defrost Relay, 10A, SPST
    • Aux1 Relay, 10A, SPST
    • Aux2 Relay 10A, SPST
  • Auxiliary Relay Outputs
    • Lighting
    • Automated Night-Blinds
    • Defrost
    • Independent Fans Control
    • Alarm
  • Control Range
    • -45C to 99C, resolution 1C
    • -49F to 185F, resolution 1F
  • Power Input
    • 1.5VA
  • Inputs
    • 1 Probe Input for Compressor/Ambient/Cabinet/Room
      • Choice of NTC or PT100
    • 1 Probe Input for defrost
      • Choice of NTC or PT100
    • 1 Digital Input (Active High or ActiveLow) for:
      • Door Signal
      • Alarm Signal
      • Lights Signal
      • Defrost Signal
    • Optionally: The digital input port can be used as a 3rd temperature probe.
  • Connections
    • Screw Terminal
    • 300V Rated
    • 20A Current
    • 24-21 AWG
    • M5 Screw Size
  • Operating Range
    • -40°C (-40°F) to 85°C (185°F)

You must login to update the wiki.

  • Power Supply
    • 12VAC
    • 12DC
    • 110/120V
    • AC 60Hz
  • Outputs
    • Compressor Relay, 10A, SPST
    • Defrost Relay, 10A, SPST
    • Aux1 Relay, 10A, SPST
    • Aux2 Relay 10A, SPST
  • Auxiliary Relay Outputs
    • Lighting
    • Automated Night-Blinds
    • Defrost
    • Independent Fans Control
    • Alarm
  • Control Range
    • -45C to 99C, resolution 1C
    • -49F to 185F, resolution 1F
  • Power Input
    • 1.5VA
  • Inputs
    • 1 Probe Input for Compressor/Ambient/Cabinet/Room
      • Choice of NTC or PT100
    • 1 Probe Input for defrost
      • Choice of NTC or PT100
    • 1 Digital Input (Active High or ActiveLow) for:
      • Door Signal
      • Alarm Signal
      • Lights Signal
      • Defrost Signal
    • Optionally: The digital input port can be used as a 3rd temperature probe.
  • Connections
    • Screw Terminal
    • 300V Rated
    • 20A Current
    • 24-21 AWG
    • M5 Screw Size
  • Operating Range
    • -40°C (-40°F) to 85°C (185°F)

Documentation

Wiki

You must login to update the wiki.

Submit an Inquiry